Reference price :
Contact us
  • Series
    MLP
  • Model
    MLP1-230L-P/DL
  • Brand / Made in
    CITEL / FRANCE
  • Description: AC/Data surge protector for Led lighting system Class 1
  • Standards compliance: IEC 61643-11 / EN 61643-11 / UL1449 ed.5
  • Certification: EAC
  • Technology: MOV+GDT
  • Remote signaling of disconnection: No
  • SPD type : 2+3
  • Network: AC: 220-240 V single-phase I Dataline: DALI/DMX/RS485/0-10V
  • AC system: TT-TN
  • Max. AC operating voltage : AC : 305 Vac I DATA : 28 Vac
  • Residual Current : None
  • Max. discharge current : AC : 10 kA I DATA : 10 kA
  • Total Maximum discharge current : AC : 20 kA I DATA : 20 kA
  • Protection level : AC: 1.5 kV I DATA : 50 V
  • Admissible short-circuit current: 10 000 A

MLP1-230L-P/DL

AC SURGE PROTECTOR FOR LED LIGHTING SYSTEM CLASS 1

LED street lighting is now widely used for its efficiency, its energy cost savings and its life expectancy. Nevertheless this attractive technology has an important weakness: its sensitivity to transient voltages created by lightning or by power switch operations on AC network.
Due to its scattered and over-exposed location, LED lighting system will face induced surges which will create failure of its power supply, damage LED components or loss of the lighting efficiency. For these reasons, the use of relevant surge protectors located upstream the LED lighting systems is highly recommended.
CITEL offers a full range of surge protectors designed to be installed at different points on the lighting network such as streetlights, the base of poles and street cabinets.
CITEL offers solutions adapted to every type of outdoor LED lighting systems : urban, architectural, tunnels etc…
CITEL proposes a complete range of AC surge protectors specifically designed for the protection of LED lighting systems in the lantern or connection boxes.
 

MLP range is a complete range of AC surge protectors specifically designed by CITEL for the protection of LED lighting systems at the lantern. Many versions have been proposed to meet the various existing configurations : surge protection devices are available in different isolation classes (Class I, Class II) and connection type (wire or screw terminal) and equipped with additional protection for data line (RS485, DALI, 0-10V) to provide a complete solution for LED systems with control lines.
In cases of extreme aggression, the surge protector will be in a state of retirement security: according to the different versions available, an indication of the failure of the surge protector is performed by the extinction of an indicator, a AC power disconnection and / or through a remote signalisation.

 

MLP1 format and electrical diagram

Cấu tạo thiết bị chống sét tích hợp đường nguồn & dữ liệu đèn Led model MLP1-230L-W/DL và MLP1-230L-P/DL 

ELECTRICAL PROPERTIES

  • SPD type: 2+3
  • Isolation classe: I
  • Network: AC: 220-240 V single-phase / Dataline: DALI/DMX/RS485/0-10V
  • AC system: TT-TN
  • Nominal line voltage Un: 230 - 277 Vac
  • Max. AC operating voltage Uc: AC: 305 Vac / DATA: 28 Vac
  • Max. frequency f max.: DATA : 10 MHz
  • Max. load current IL: AC: 2.5 A / DATA: 300mA
  • Temporary Over Voltage (TOV) Charasteristics - 5 sec UT: 335 Vac withstand
  • Temporary Over Voltage (TOV) Charasteristics - 120 mn UT: 440 Vac disconnection
  • Residual Current Ipe: none
  • Follow current If: none
  • Nominal discharge current In: AC: 5kA / DATA: 5 kA
  • Max. discharge current Imax: AC: 10 kA / DATA: 10 kA
  • Total Maximum discharge current Imax Total: AC: 20 kA I DATA: 20 kA
  • Withstand on Combinaison waveform IEC 61643-11 Uoc: AC: 10 kV / 5 kA
  • Withstand on overvoltages IEEE C62.41.1: 10 kV / 10 kA
  • Admissible short-circuit current Isccr: 10 000 A
  • Protection mode(s): Common/Differential mode
  • Protection level @ In (8/20µs) Up: AC: 1.5 kV (L/N, L/PE) / DATA: 50 V

MECHANICAL PROPERTIES

  • Network type: AC + DATA
  • Technology: MOV + GSG
  • Connection to Network: AC: Screw terminal - 1.5mm² max / DATA: Screw terminal - 1mm² max.
  • Mounting: on plate
  • Housing material: Thermoplastic UL94 V-0
  • Operating temperature Tu: -40/+85°C
  • Protection rating: IP20
  • Failsafe be behavior: Disconnection and AC line cut-off
  • Disconnection indicator: Led green OFF and AC network cut-off
  • Voltage/operating indicator: Green Led ON
  • Remote signaling of disconnection: no

DISCONNECTORS

  • Thermal disconnector: Internal
  • Installation ground fault breaker: Type S or delayed

NORMS

  • Standards compliance: IEC 61643-11 / EN 61643-11 / UL1449 
  • Certification: EAC 