Reference price :
Contact us
  • Series
    MJ8
  • Model
    MJ8-C6A
  • Brand / Made in
    CITEL / FRANCE
  • Ethernet Cat.6A Surge Protector
  • Up to 10Gigabit Ethernet compatible
  • Hybrid GDT and Diode Technology
  • Bi-Directional Protection
  • Shielded Connector Configurations
  • Max. frequency > 500 MHz
  • Nominal discharge current (8/20µs) 2 kA (L/L), 0.5 kA (L/G)
  • Impulse current (10/350µs) 0.5 kA
  • DIN Rail, Screw Lug, and Flange Mounting
  • Compliance IEC/EN 61643-21, UL497B

MJ8-C6A

Surge protector for 10Gb Ethernet (Cat6A, RJ45)

 
MJ8-C6A is a replacement product for MJ8-CAT6S

 

MJ8-C6A Ethernet network surge protectors are designed for computer networks with very fast data transfer speeds up to 10 Gbit/s for the Category 6A networks with shielded cable (STP). Featured with in/out RJ45 connectors.

Their GDT/Diodes circuit gives them the discharge capacity necessary for the protection of inter-building connections. In order to cover the many various types of networking applications

Thiết bị chống sét MJ8-CAT6S bảo vệ cho các đường mạng kết nối

 

ELECTRICAL PROPERTIES

  • Network: 10Gigabit Ethernet - Cat 6A cabling specification
  • Nominal line voltage Un: 5 Vdc
  • Max. DC operating voltage Uc: 8 Vdc
  • Max. load current IL: 1 A
  • Max. data rate: 10 Gbps
  • Max. frequency fmax.: > 500 MHz
  • Insertion loss: < 1 dB
  • Protection level Up: 20 V
  • Impulse current Iimp (10/350µs): 500 A
  • Line/Line Nominal discharge current (8/20µs) In L/L: 500 A
  • Line/Ground Nominal discharge current (8/20µs) In L/PE: 2000 A

MECHANICAL PROPERTIES

  • Technology: GDT+Clamping diode
  • SPD configuration: 4 pairs+shielded
  • Connection to Network: RJ45 shielded connectors Female input/output
  • Format: Connector RJ45
  • Mounting: Mounting flange, Screw lug, DIN Rail
  • Housing material: Aluminium
  • Operating temperature: -40/+85°C
  • Protection rating: IP20
  • Failsafe mode: Short-circuit
  • Disconnection indicator: transmission interrupt - default mode 2
  • Pinout: (1-2)(3-6)(4-5)(7-8)

STANDARDS

  • Standards compliance: IEC 61643-21/ EN 61643-21 / UL497B / IEEE 802-3af/3at/3bt/ ANSI/TIA-568-C.1
INSTALLATION
The surge protector for IT networks must be installed while respecting the following principles:
  • SPDs must be installed on the both sides of the transmission line (e.g. server side and terminal equipment side)
  • The surge protector and the protected equipment must be interconnected with the bonding network of the installation.
  • The earthing conductor (between the earth output of the SPD and the bonding circuit of the installation) must be as short as possible (less than 0.50 m).
  • The AC power supply of the equipment must also be surge protected.
closet