Reference price :
Contact us
  • Series
    DPVN1-6CS
  • Model
    DPVN1-6CS-21Y-600
  • Brand / Made in
    CITEL / FRANCE
  • Type 1+2 PV surge protector 600 Vdc - CTC Technology
  • Network: PV 600 Vdc
  • Nominal PV voltage Uocstc: 500 Vdc
  • Max. PV operating voltage: 600 Vdc
  • Discharge current In/ Imax : 20 kA/ 40 kA (8/20 μs)
  • Total Maximum discharge current : 60 kA (8/20 μs)
  • Impulse currents Iimp/Itotal: 6.25/12.5 kA (10/350µs)
  • Current withstand short circuit PV Iscpv: 15 kA
  • Residual Current Ipe : < 0.1 mA
  • Follow current If: None
  • Protection mode(s): Common/Differential mode
  • Technology: MOV
  • Remote signaling of disconnection: Output on changeover contact
  • Standards compliance: IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5

DPVN1-6CS-21Y-600

The DPVN1 is CITEL's new series of type 1+2 SPDs for Photovoltaic. Based on CITEL's patented CTC Technology, the DPVN1 incorporates a thermosensitive separation point placed at the center of the SPD guaranteeing the safest disconnection on the market. The products are designed to be mounted on a DIN rail. Compact and equipped with a failure indicator, these products are easy to install and maintain.

Electrical Characteristics

  • SPD type 1+2
  • Network: PV 600 Vdc
  • Nominal PV voltage Uocstc: 500 Vdc
  • Max. PV operating voltage Ucpv: 600 Vdc
  • Residual Current (Leakage current to Ground) Ipe: < 0.1 mA
  • PV Permanent Operating current (Current consumption at Ucpv) Icpv: < 0.1 mA
  • Follow current If: None
  • Nominal discharge current (15 x 8/20 μs impulses) In: 20 kA
  • Max. discharge current (max. withstand @ 8/20 μs by pole) Imax: 40 kA
  • Total Maximum discharge current (max. total withstand @ 8/20 μs) Imax Total: 60 kA
  • Impulse current by pole (max. withstand 10/350μs by pole) Iimp: 6.25 kA
  • Total lightning current (max. total withstand @ 10/350μs) Itotal: 12.5 kA
  • Current withstand short circuit PV Iscpv: 15 000 A
  • Connection mode(s): +/-/PE
  • Protection mode(s): Common/Differential mode
  • Protection level +/- @ In (8/20μs) Up: 2.3 kV
  • Protection level +/PE (-/PE) @ In (8/20μs) Up: 2.3 kV

Mechanical Characteristics

  • Technology MOV
  • Connection to Network By: screw terminals: 2.5-25mm² (35mm²) / by bus
  • Format: Compact monobloc box
  • Mounting: Symmetrical rail 35 mm (EN 60715)
  • Housing material: Thermoplastic UL94 V-0
  • Operating temperature Tu: -40/+85°C
  • Protection rating: IP20
  • Failsafe mode: All pole disconnection from PV network
  • Disconnection: indicator 1 mechanical indicator - Red/Green
  • Remote signaling of disconnection: Output on changeover contact
  • Dimensions: See diagram - 2.5TE (EN43880)
  • Weight: 0.500 kg

Disconnectors

  • Thermal disconnector: CTC Technology integrated
  • Back-up protection device: Without

Standards

  • Standards compliance IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5

Installation

DS60VGPV-1500G/51 surge protector is connected in parallel on the DC network 

  • The total length of parallel connection wires to DC network must be lower than 0.5 m in order not to increase the protection level (Up) provided by the SPD.
  • Wiring is made by screw connections. On some models, a distribution bus can be used.
  • The protection wire coming from the SPD must be connected to the bonding bar of the electrical panel. Paralleling the protection wire with phases conductors must be avoided.
  • Local earthing resistance must be in compliance with the electrical rules.