Overvoltage protection system for the Factory of FUCHS Lubricants VN

  • Category
    Industry
  • Location
    Bà Rịa Vũng Tàu
  • CHỦ ĐẦU TƯ
    FUCHS LUBRICANTS VIETNAM COMPANY LTD
  • NGÀY THỰC HIỆN
    2023
  • SỐ LƯỢNG SẢN PHẨM
    CITEL SPD
  • TRẠNG THÁI DỰ ÁN
    The Project had finished

Description

FUCHS is a global Group with German roots that has developed, produced and sold lubricants and related specialties for 90 years – for virtually all areas of application and sectors. With 58 companies and more than 5,700 employees worldwide, the FUCHS Group is the leading independent supplier of lubricants.

The factory Fuchs Lubricants Vietnam is located in Lot F5, D3 Street, Phu My 3 Industrial Park, Phuoc Hoa Ward, Phu My Town, Ba Ria - Vung Tau Province, Viet Nam

As electronic components become more sensitive to electromagnetic interference as well as the factory's location where there is the high density of lightning strikes thus the system is easily effected of the impact lightning strikes, therefore the company has equipped surge protection systems to protect the entire system plant, especially focusing to protect for electrodynamics and control systems.

Thy An Engineering Co., Ltd. - TAEC is honored to be their partner who provides a comprehensive lightning protection solution, using products from CITEL/France to protect the entire electrical system against electrical hazards and other potential dangers.

The handover has been excuted and the system has remained stable over a period of years. The system contribute to ensuring safety and developing production in the achievement of the FUCHS VietNam's goals
 

The factory installation images

 

 

 

  

  

 

Location

Products Used

Model: MS200-240Y
  • UL 1449 5th Ed. Type 1 listed Surge Protective Device
  • System voltage: 240/415 Vac
  • System: Wye 3Ph+N+G
  • Maximum Discharge Current per phase Imax (8/20μs): 220 kA 
  • Impulse Discharge Current per phase Iimp (10/350): 12.5 kA
  • All mode of protection
  • 200 kA short-circuit fault current rated
  • Multi-redundant protection circuit per phase
  • Full on-board diagnostics - LED indicators, remote and audible alarms
  • EMI/RFI noise filtering
  • NEMA 4/4X/12 enclosure
  • Lightning counter (option)
Model: M50F-230S-A
  • System voltage: 230 V
  • System: 2W+G (single)
  • Hybrid MOV-GSG Technology and EMI/RFI filtering
  • UL1449 Type 2 LISTED
  • 50kA Surge Current Rating per mode
  • Extended life with no leakage current
  • Visual LED fault indicator and audible alarm
  • NEMA 6: indoor / outdoor used
  • Hardwired connection
Model: DS254E-300/G
  • Type 1 + 2 unipolar surge protector
  • Iimp total: 100 kA on 10/350µs impulse
  • Imax : 140 kA on 8/20µs impulse
  • Internal disconnections, status indicators
  • Remote signaling
  • IEC 61643-11, EN 61643-11 and UL1449 ed.5 compliance
Model: DAC1-13VG-31-275
  • Type 1 + 2 + 3 AC surge protector
  • VG Technology
  • Network: 230/400 V 3-phase+N
  • In : 20 kA
  • Iimp : 12.5 kA on 10/350µs impulse
  • No leakage current
  • Pluggable module for each phase
  • Remote signaling (option)
  • Optimized to TOV
  • EN 61643-11, IEC 61643-11 certified
  • UL1449 ed.5 compliance
Model: DAC1-13VG-20-275
  • Type 1 + 2 + 3 AC surge protector
  • VG Technology
  • Network: 230 V single-phase
  • In : 20 kA
  • Iimp : 12,5 kA on 10/350µs impulse
  • No leakage current
  • Pluggable module for each phase
  • Remote signaling (option)
  • Optimized to TOV
  • EN 61643-11, IEC 61643-11 certified
  • UL1449 ed.5 compliance
Model: DAC50VG-31-275
  • Description: Type 2+3 AC surge protector - 3-phase+N
  • Standards compliance: IEC 61643-11 / EN 61643-11 / UL1449 ed.5
  • Certification: KEMA / EAC
  • Technology: VG Technology (MOV+GSG)
  • SPD configuration: 3-phase+Neutral
  • Remote signaling of disconnection: option DAC50VGS-31-275: output on changeover contact
  • Network: 230/400 V 3-phase+N
  • AC system: TT-TNS
  • Max. AC operating voltage: 275 Vac
  • Residual Current: None
  • Max. discharge current: 50 kA
  • Total Maximum discharge current: 50 kA
  • Admissible short-circuit current: 50 000 A
Model: DS42VG-230
  • Description: Type 2+3 AC surge protector - single-phase
  • Standards compliance: IEC 61643-11 / EN 61643-11 / UL1449 ed.5
  • Certification: UL Recognized
  • Technology: VG Technology (MOV+GSG)
  • Remote signaling of disconnection: option DS42VGS-230 : output on changeover contact
  • Network: 230 V single-phase
  • AC system: TN
  • Max. AC operating voltage : 255 Vac
  • Residual Current : None
  • Max. discharge current : 40 kA
  • Total Maximum discharge current : 80 kA
  • Admissible short-circuit current: 25 000 A
Model: DS220-24DC
  • DC power surge protector
  • 24 Vdc
  • Compact design
  • Imax : 20 kA
  • Pluggable module
  • Very low Up protection level