Summary of DLA surge protection product line for signal lines

Saturday, 29/07/2023, 16:53

 

CITEL range

Line configuration

Pluggable Module

Line transmission when

plug-out

Default mode (following IEC61643-21)

Shield manage- ment

Wire Connection

Default Signalling

Default Remote Signalling

Width

Imax

Max Load current

DLA

1 pair

Y

On

Mode 2

Y

screw

N

N

13 mm

20 kA

0.3 A

DLA/R

1 pair

Y

On

Mode 2

Y

spring

N

N

13 mm

20 kA

0.3 A

DLAW

1 pair

Y

Off

Mode 2

Y

screw

N

N

13 mm

20 kA

0.3 A

DLAW/R

1 pair

Y

Off

Mode 2

Y

spring

N

N

13 mm

20 kA

0.3 A

DLAHW/R

1 pair

Y

Off

Mode 2

Y

spring

N

N

13 mm

20 kA

2.4 A

DLAH

1 pair

Y

On

Mode 2

Y

screw

N

N

13 mm

20 kA

2.4 A

DLAH/R

1 pair

Y

On

Mode 2

Y

spring

N

N

13 mm

20 kA

2.4 A

DLA2

2 pairs

Y

On

Mode 2

Y

screw

N

N

18 mm

20 kA

0.3 A

DLA-IS

1 pair + 0V

Y

On

Mode 2

Y

screw

N

N

18 mm

20 kA

2.4 A

DLAS1

1 pair

Y

On

Mode 2

Y

screw

Y

N

18 mm

20 kA

0.3 A

DLAS1/R

1 pair

Y

On

Mode 2

Y

spring

Y

N

18 mm

20 kA

0.3 A

DLAWS1

1 pair

Y

Off

Mode 2

Y

screw

Y

N

18 mm

20 kA

0.3 A

DLAWS1/R

1 pair

Y

Off

Mode 2

Y

spring

Y

N

18 mm

20 kA

0.3 A

DLATS1

1 pair

Y

On

Mode 2

Y

screw

Y

Y

18 mm

20 kA

0.3 A

DLATS1/R

1 pair

Y

On

Mode 2

Y

spring

Y

Y

18 mm

20 kA

0.3 A

DLAWTS1

1 pair

Y

Off

Mode 2

Y

screw

Y

Y

18 mm

20 kA

0.3 A

DLAWTS1/R

1 pair

Y

Off

Mode 2

Y

spring

Y

Y

18 mm

20 kA

0.3 A

DLC

1 pair

N

NA

Mode 2

N

spring

N

N

6 mm

10 kA

0.3 A

DLU

1 pair

N

NA

Mode 2

Y

screw

N

N

18 mm

20 kA

0.3 A

DLU2

2 pairs

N

NA

Mode 2

N

screw

N

N

18 mm

20 kA

0.3 A

DLUH

1 pair

N

NA

Mode 2

Y

screw

N

N

18 mm

20 kA

2.4 A

DLUH2

2 pairs

N

NA

Mode 2

N

screw

N

N

18 mm

20 kA

2.4 A

 

Other news

Wednesday,04/09/2024
Tuesday,06/12/2022
Mission-critical systems, subjected to even properly terminated lightning strikes, suffer unacceptable damages from secondary and electro-magnetic effects. The advancement of electronic technology over the past several decades demands a constant innovation in lightning protection technology as well. Alltec Corporation takes pride in the continual development and improvement of our TerraStat® line of charge dissipation/charge redistribution products.
Wednesday,07/12/2022
This technology is the exclusive and patented technology of CITEL based on the use of specific types of Gas tubes: GSG. These components, the result of over 75 years of experience in the gas discharge tube field, have a behavior adapted to the power network and provide robustness and working stability: their association with varistors combines the advantages of both technologies.
Thursday,09/05/2024
Selection Guide - OFC Series Medium Intensity (OBSTA / FRANCE)
Thursday,02/05/2024
Selection Guide - Navilite Series Low Intensity (OBSTA / FRANCE)
Tuesday,13/06/2023
Ý tưởng sử dụng các xung laser mạnh để điều hướng tia chớp đã được khám phá trước đây trong điều kiện phòng thí nghiệm. Tuy nhiên, trước đây chưa có bất kỳ cuộc thử nghiệm để chứng minh được phương pháp này sẽ hoạt động ra sao ngoài thực tế. Tiến sĩ Houard và các đồng nghiệp đã tiến hành một loạt thử nghiệm vào mùa hè năm ngoái trên đỉnh núi Santis ở phía đông bắc Thụy Sĩ.
Wednesday,24/05/2023
Khuôn hàn hóa nhiệt Apliweld là một loại khuôn bằng Graphite do công ty AT Tây ban nha sản xuất, được dùng để hàn nối liên kết và định vị giữa các đối tượng cần hàn với nhau như thanh, cây, cáp hoặc ống kim loại. Khuôn hàn hóa nhiệt thường được sử dụng với thuốc hàn Apliweld hoặc các loại bột hàn hóa nhiệt khác, đây là công nghệ hàn dựa trên phản ứng nhiệt nhôm giữa các thành phần vật liệu với nhau.
Tuesday,06/12/2022
The DAT Tester is a battery-operated tester to verify the correct operation of DAT CONTROLER®PLUS series ESE Lightning Air Terminals. A high voltage is applied to the Air Terminal. Two test leads are used to connect the instrument and Air Terminal to be tested. The test unit displays a green LED to indicate air terminal is operational or two red LEDs to indicate if the air terminal is faulty. The test unit contains a rechargeable battery to allow portable use in the field.