MY PHUOC HOSPITAL

  • Category
    Education & Health
  • Location
  • CHỦ ĐẦU TƯ
    BECAMEX
  • NGÀY THỰC HIỆN
    2014
  • SỐ LƯỢNG SẢN PHẨM
    ALLTEC; CITEL
  • TRẠNG THÁI DỰ ÁN
    Đã hoàn thành

Description

Lightning Protection for My Phuoc Hospital

 

Tòa nhà BV Mỹ phước đang được xây mới

Tòa nhà BV Mỹ phước đang được xây mới

 

ThyAn triển khai lắp đặt hệ thống theo tiến độ của công trình

ThyAn triển khai lắp đặt hệ thống theo tiến độ của công trình

 

Location

Products Used

Model: TSP-60
  • Certified advance time (ΔT): 61 µs
  • Protection radius: 107 m (h=6m, Level IV)
  • Suitable for use with lightning protection cable or copper tape
  • Rugged yet aesthetically pleasing construction
  • Suitable for most environments, including corrosive atmospheres
  • Lightweight and low wind loading
  • No internal electronics or power supply
  • Reliable performance in all weather conditions
  • NFC 17–102 and UNE 21186 tested and certified
Model: DS154E-300/G
  • SPD type (following IEC tests): 1+2
  • Network: 230/400 V 3-phase+N, AC system: TT-TN
  • Nominal line voltage Un: 230 Vac,
  • Max. AC operating voltage Uc: 300 Vac
  • Max. discharge current (max. withstand @ 8/20 µs by pole) Imax: 140 kA
  • Impulse current by pole (max. withstand 10/350µs by pole) Iimp: 15 kA
  • Residual voltage (at Iimp) Ures: 0.9 kV
  • Protection level (at In) Up: 2 kV
  • Remote signaling of disconnection: output on changeover contact
  • Standards compliance: NF EN 61643-11 / IEC 61643-1 / EN 61643-11 / UL1449 

Model: PL24-CAT6
  • Surge protector for CAT6
  • 24 ports
  • 19'' patch panel 1 U
  • 100/1000/10Gigabit Ethernet network compliance
  • Connectors RJ45 shielded
  • Bi-directionnel
Model: M160-220Y
  • Type 2 AC Power Surge Protective Device
  • System voltage: 220/380 Vac 
  • System: Wye 3Ph+N+G
  • Maximum Discharge Current per phase Imax (8/20μs): 160 kA 
  • All mode of protection
  • 200 kA short-circuit fault current rated
  • Multi-redundant protection circuit per phase
  • Full on-board diagnostics - LED indicators, remote and audible alarms
  • EMI/RFI noise filtering
  • NEMA 4 enclosure
  • Lightning counter (option)
Model: DS42VG-230
  • Description: Type 2+3 AC surge protector - single-phase
  • Standards compliance: IEC 61643-11 / EN 61643-11 / UL1449 ed.5
  • Certification: UL Recognized
  • Technology: VG Technology (MOV+GSG)
  • Remote signaling of disconnection: option DS42VGS-230 : output on changeover contact
  • Network: 230 V single-phase
  • AC system: TN
  • Max. AC operating voltage : 255 Vac
  • Residual Current : None
  • Max. discharge current : 40 kA
  • Total Maximum discharge current : 80 kA
  • Admissible short-circuit current: 25 000 A
Model: MJ8-C6A
  • Ethernet Cat.6A Surge Protector
  • Up to 10Gigabit Ethernet compatible
  • Hybrid GDT and Diode Technology
  • Bi-Directional Protection
  • Shielded Connector Configurations
  • Max. frequency > 500 MHz
  • Nominal discharge current (8/20µs) 2 kA (L/L), 0.5 kA (L/G)
  • Impulse current (10/350µs) 0.5 kA
  • DIN Rail, Screw Lug, and Flange Mounting
  • Compliance IEC/EN 61643-21, UL497B

Other project Education & Health

Bệnh Viện Huyện Củ Chi - Tp. Hồ Chí Minh

Bệnh viện An Giang